Huawei S6730-H28X6CZ-V2 switch with 28-port 10G SFP+, 6-port 40G QSFP28 optional license for upgrade to 100G,
2 power modules slots, without power modules equipped
Forwarding Performance: 490Mpps
Switching Capacity: 1.76 Tbit/s/2.4 Tbit/s
1+1 power backup
1 expansion slot
Non-PoE switch
Huawei CloudEngine S6730-H-V2 series 10GE switches are next-generation enterprise-class core and aggregation switches that provide 10GE downlink optical ports and 100GE uplink optical ports, and provide one extended slot.
Tech Specs
| Basic Information | |
| Part Number | 02354VUF |
| Model | S6730-H28X6CZ-V2 |
| Description | S6730-H28X6CZ-V2 (28*10GE SFP+ ports, 6*40GE QSFP28 ports, optional license for upgrade to 6*100GE QSFP28 ports, 1*expansion slot, without power module) |
| Technical Specifications | |
| Height [mm] | 43.6 mm |
| Depth [mm] | 420.0 mm |
| Wide [mm] | 442.0 mm |
| Chassis height [U] | 1 |
| Weight with packaging | 10.04 (22.13) |
| Weight without packaging | 7.06 (15.56) |
| Maximum power consumption [W] | 263 |
| Typical power consumption [W] | 203 |
| Maximum heat dissipation [BTU/h] | 897.38 |
| Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
| Typical heat dissipation [BTU/h] | 692.66 |
| Power supply mode | Pluggable power supply |
| Input voltage range [V] | – AC input: 90 V AC to 290 V AC; 45–65 Hz |
| – High-voltage DC input: 190 V DC to 290 V DC | |
| – DC input: -38.4 V DC to -72 V DC | |
| Rated input voltage [V] | – AC input: 100 V AC to 240 V AC; 50/60 Hz |
| – High-voltage DC input: 240 V DC | |
| – DC input: –48 V DC to –60 V DC | |
| Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
| Number of power slots | 2 |
| Number of card slots | 1 |
| Memory | 4 GB |
| Flash memory | 2 GB in total. To view the available flash memory size, run the display version command. |
| Redundant power supply | 1+1 |
| Pluggable AC and DC power modules can be used together in the same switch. | |
| Types of fans | Pluggable |
| Noise at normal temperature (acoustic pressure) | 39.72 |
| Noise at normal temperature (acoustic power) | 53.4 |
| Airflow direction | Air intake from front and right and air exhaust from rear |
| Restriction on the operating temperature variation rate | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
| Devices cannot start when the temperature is lower than 0°C (32°F). | |
| When the QSFP-100G-ER4 optical module is used, the operating temperature ranges from -5°C to +40°C (23°F to 104°F). | |
| Long-term operating temperature | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
| Storage temperature | –40°C to +70°C (–40°F to +158°F) |
| Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) |
| Storage altitude | 0-5000 m (0-16404 ft.) |
| Long-term operating altitude | 0–5000 m (0–16404 ft.) |
| MTBF [year] | 52.24 |
| MTTR [h] | 2 |
| Availability | >0.99999 |
| Maximum number of physical ports on the entire device | 34 |
| Maximum number of 100GE ports | 6 |
| Maximum number of 40GE ports | 6 |
| Maximum number of 25GE ports | 0 |
| Maximum number of 10GE ports | 28 |
| Maximum number of GE ports | 28 |
| Maximum number of FE ports | 0 |
| 10GE optical interface | 28 |
| 40G optical interface | 6 |
| 100G optical interface | 6 |
| USB | Supported |
| Console port | RJ45 |
| Eth Management port | RJ45 |
| Service port surge protection | – |
| Power supply surge protection | – Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode |
| – Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode | |
| RPS input | Not supported |
| PoE | Not supported |

Reviews
There are no reviews yet.