CloudEngine S6750-H36C
Huawei S6750-H36C switch with 32-port 40/100 GE QSFP28, 4-port 40/100 GE QSFP28 (4 x 200G optical ports will be supported for uplink ports by license)
Power modules supported:
PAC1K2S12-PB, 1200W AC power module
PDC1K2S12-CE, 1200W DC power module
Huawei CloudEngine S6750-H series 100GE switches are next-generation enterprise-class core switches that offer high performance, high reliability, cloud management, and intelligent operations and maintenance (O&M). They build on an industry leading software and hardware platform and are purpose-built with security, IoT, and cloud in mind. With these traits, CloudEngine S6750-H can be widely used in enterprise campuses, colleges/universities, data centers, and other scenarios.
CloudEngine S6750-H series 100GE switches offer 100GE port types, flexibly adapting to diversified network bandwidth requirements. They also support cloud management and implement cloud-managed network services throughout the full lifecycle from planning, deployment, monitoring, experience visibility, and fault rectification, all the way to network optimization, greatly simplifying network management.
Technical Specifications | |
Switching Capacity | 7.2Tbps/ 8Tbps |
Fixed Ports | 36-port 100GE QSFP28 |
Memory | 8 GB |
Flash memory | Physical space: 4 GB |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Supported |
RTC | Supported |
Number of power slots | 2 |
Number of fans modules | 5 |
Redundant power supply | 1+1 Pluggable AC and DC power modules can be used together in the same switch. |
Power supply mode | Pluggable power supply |
Rated input voltage [V] | AC input: 100 V AC to 240 V AC; 50/60 Hz High-voltage DC input: 240 V DC DC input: –48 V DC to –60 V DC |
Input voltage range [V] | AC input: 90 V AC to 290 V AC; 45–65 Hz High-voltage DC input: 190 V DC to 290 V DC DC input: -38.4 V DC to -72 V DC |
Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Power supply surge protection [kV] | Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode |
Ingress protection level (dustproof/waterproof) | IP20 |
Types of fans | Pluggable |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction | Air intake from front, air exhaustion from rear (front-to-rear) |
Certification | EMC certification Safety certification Manufacturing certification |
Dimensions with packaging (H x W x D) [mm] | 185.0 mm x 650.0 mm x 550.0 mm |
Chassis height [U] | 1 |
Chassis material | Metal |
Weight without packaging [kg] | 6.72 |
Weight with packaging [kg] | 11 |
Typical power consumption [W] | 30% traffic under the ATIS standard and dual power modules: 537 W |
Typical heat dissipation [BTU/hour] | 30% traffic under the ATIS standard and dual power modules: 1832.30 |
Maximum power consumption [W] | 100% traffic under the ATIS standard and dual power modules: 558 W |
High temperature 45°C, 100% traffic, long-distance optical module, and dual power modules: 679 W | |
Maximum heat dissipation [BTU/hour] | 100% traffic under the ATIS standard and dual power modules: 1903.95 |
High temperature 45°C , 100% traffic, long-distance optical module, and dual power modules: 2316.82 | |
Static power consumption [W] | 317 |
MTBF [years] | 27.77 |
MTTR [hours] | 2 |
Availability | > 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 57.7 |
Noise at normal temperature (acoustic pressure) [dB(A)] | 57.2 |
Long-term operating temperature [°C] | –5°C to +45°C at an altitude of 0 to 1800 m |
Restriction on the operating temperature variation rate [°C] | When the altitude is 1800–5000 m, the highest operating temperature reduces by 1°C every time the altitude increases by 220 m. Devices cannot start when the temperature is lower than 0°C. When the QSFP-100G-ER4 optical module is used, the operating temperature ranges from -5°C to +40°C . |
Storage temperature [°C] | –40°C to +70°C |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m] | 0–5000 m |
Storage altitude [m] | 0-5000 m |
Reviews